1. Home
  2. NFPA
  3. CWBSP Dumps

Eliminate Risk of Failure with NFPA CWBSP Exam Dumps

Schedule your time wisely to provide yourself sufficient time each day to prepare for the NFPA CWBSP exam. Make time each day to study in a quiet place, as you'll need to thoroughly cover the material for the Certified Water-Based Systems Professionals exam. Our actual NFPA Certifications exam dumps help you in your preparation. Prepare for the NFPA CWBSP exam with our CWBSP dumps every day if you want to succeed on your first try.

All Study Materials

Instant Downloads

24/7 costomer support

Satisfaction Guaranteed

Q1.

How much pressure is lost to friction as 1,200 gpm (4542 L/min) travels through 200 ft (61 m) of 5 in. (130 mm) schedule 40 steel pipe with a C-factor of 120?

Answer: C

See the explanation below.

The pressure loss due to friction for 1,200 gpm traveling through 200 ft of 5 in. schedule 40 steel pipe with a C-factor of 120 is approximately 21 psi (1.45 bar). This calculation takes into account the flow rate, pipe length, diameter, and roughness factor.


Q2.

What is the minimum temperature rating of ceiling sprinklers in roll paper stored at 15 ft. (4.6 m) or less?

Answer: C

See the explanation below.

The minimum temperature rating for ceiling sprinklers in roll paper storage areas that are 15 ft or less in height is typically 150F (66C). This rating is selected to provide a buffer between the ambient temperature conditions and the activation temperature of the sprinklers, preventing accidental activation.


Q3.

A restaurant service area has an 18 ft (5.5 m) high T-Bar ceiling throughout. Using quick-response sprinklers in a wet

sprinkler system, what is the minimum area and density that should be calculated?

Answer: D

See the explanation below.

In a restaurant service area with an 18 ft high T-Bar ceiling and using quick-response sprinklers in a wet system, the minimum area and density that should be calculated is typically 0.15 gpm over 1,080 ft (6.1 mm/min over 100.3 m), considering the ceiling height and occupancy.


Q4.

What is the maximum pressure rating when using standard weight pattern malleable iron fittings that are 6 in. (150 mm) in size and smaller?

Answer: C

See the explanation below.

Standard weight pattern malleable iron fittings that are 6 inches in size and smaller typically have a maximum pressure rating of 300 psi (21 bar). This rating ensures that the fittings can withstand the pressure demands of most fire sprinkler systems without failure.


Q5.

Where must a diesel engine driven fire pump's fuel tank be located for areas subject to temperatures below 32F (0)?

Answer: A

See the explanation below.

The fuel tank for a diesel engine-driven fire pump must be located in the same room as the fire pump, especially in areas subject to freezing temperatures, to ensure that the diesel fuel remains at a usable temperature and the pump is readily available for operation during an emergency.


Are You Looking for More Updated and Actual NFPA CWBSP Exam Questions?

If you want a more premium set of actual NFPA CWBSP Exam Questions then you can get them at the most affordable price. Premium NFPA Certifications exam questions are based on the official syllabus of the NFPA CWBSP exam. They also have a high probability of coming up in the actual Certified Water-Based Systems Professionals exam.
You will also get free updates for 90 days with our premium NFPA CWBSP exam. If there is a change in the syllabus of NFPA CWBSP exam our subject matter experts always update it accordingly.