Schedule your time wisely to provide yourself sufficient time each day to prepare for the NFPA CFI-I exam. Make time each day to study in a quiet place, as you'll need to thoroughly cover the material for the Certified Fire Inspector I exam. Our actual NFPA Certifications exam dumps help you in your preparation. Prepare for the NFPA CFI-I exam with our CFI-I dumps every day if you want to succeed on your first try.

All Study Materials

Instant Downloads

24/7 costomer support

Satisfaction Guaranteed

Q1.

Sprinkler systems in garages that are used only for the parking of vehicles shall be designed for which of the following hazard classifications?

Answer: B

See the explanation below.

Comprehensive and Detailed Step-by-Step Explanation:

Hazard Classifications for Sprinkler Systems:

Per NFPA 13 (Standard for the Installation of Sprinkler Systems), Section 5.3.2, garages used only for parking vehicles are classified as Ordinary Hazard (Group 1).

Why Ordinary Hazard (Group 1) Applies:

Vehicle parking areas present moderate fire loads due to combustible materials (tires, upholstery, fuel tanks).

Other Options Explained:

Option A (Light hazard): Incorrect; light hazard applies to areas with minimal combustible materials.

Option C (Ordinary hazard Group 2): Higher risk areas like repair shops fall into Group 2.

Option D (High hazard): Not applicable; garages used solely for parking do not present high hazard risks.

Summary:

Sprinkler systems in garages used only for parking vehicles are designed for Ordinary Hazard (Group 1).


Q2.

What is the minimum required total stair width in a non-sprinklered hotel with an occupancy capacity of 650?

Answer: B

See the explanation below.

Comprehensive and Detailed Step-by-Step Explanation:

Egress Width Calculation:

According to NFPA 101 (Life Safety Code), Section 7.3.3.1, for non-sprinklered occupancies, the required stair width is 0.3 inches per occupant.

Calculation:

Occupancy capacity = 650 people

Required stair width = 0.3in.650=195inches0.3 \, \text{in.} \times 650 = 195 \, \text{inches}0.3in.650=195inches.

Other Options Explained:

Option A (130 in): Too small for 650 occupants.

Option C (217 in): Exceeds the requirement.

Option D (455 in): Far exceeds the requirement.

Summary:

The minimum required total stair width for a non-sprinklered hotel with an occupancy capacity of 650 is 195 inches.


Q3.

What is the maximum amount of Class IC flammable liquid permitted to be stored in the basement of a building?

Answer: A

See the explanation below.

Comprehensive and Detailed Step-by-Step Explanation:

Storage of Flammable Liquids:

Per NFPA 30 (Flammable and Combustible Liquids Code), Section 9.4.1, Class IC flammable liquids are not permitted to be stored in basements due to fire and explosion risks.

Why 0 Gallons is the Limit:

Flammable liquids with low flash points present significant fire hazards in basements due to limited ventilation and difficulty accessing these areas during emergencies.

Other Options Explained:

Options B (16 gal), C (64 gal), and D (180 gal): NFPA 30 explicitly prohibits Class IC liquids in basements, so these are not allowed.

Summary:

The maximum amount of Class IC flammable liquid allowed in a basement is 0 gallons.


Q4.

A fully sprinklered structure containing 1,500 sprinklers requires a minimum supply of how many spare sprinklers?

Answer: C

See the explanation below.

Comprehensive and Detailed Step-by-Step Explanation:

Spare Sprinkler Requirements:

According to NFPA 13 (Standard for the Installation of Sprinkler Systems), Section 6.2.9, the required number of spare sprinklers is based on the total number of sprinklers in the system:

0--300 sprinklers: Minimum of 6 spare sprinklers.

301--1,000 sprinklers: Minimum of 12 spare sprinklers.

1,001--2,000 sprinklers: Minimum of 18 spare sprinklers.

Why 18 Spare Sprinklers are Required:

For a system containing 1,500 sprinklers, the requirement falls within the range of 1,001 to 2,000 sprinklers, mandating 18 spare sprinklers.

Other Options Explained:

Option A (6) and Option B (12): Insufficient for 1,500 sprinklers.

Option D (24): Exceeds the required minimum.

Summary:

A system with 1,500 sprinklers requires a minimum of 18 spare sprinklers.


Q5.

Which of the following requires an emergency plan?

Answer: D

See the explanation below.

Comprehensive and Detailed Step-by-Step Explanation:

Emergency Plan Requirements:

According to NFPA 101 (Life Safety Code), Section 12.4.1, special occupancies like special amusement buildings are required to have an emergency plan due to their unique fire hazards, including lighting effects, confined pathways, and high fire risk.

Why Special Amusement Buildings Need a Plan:

These structures often have complex layouts and unique hazards, increasing the need for a clear and practiced emergency plan.

Other Options Explained:

Option A (Parking garage): Typically does not require an emergency plan unless additional hazards exist.

Option B (Grocery store): Emergency plans are usually required for larger assembly or high-risk occupancies.

Option C (Two-story office building): Generally does not require an emergency plan unless it exceeds occupancy thresholds.

Summary:

A special amusement building requires an emergency plan due to its unique fire and egress hazards.


Are You Looking for More Updated and Actual NFPA CFI-I Exam Questions?

If you want a more premium set of actual NFPA CFI-I Exam Questions then you can get them at the most affordable price. Premium NFPA Certifications exam questions are based on the official syllabus of the NFPA CFI-I exam. They also have a high probability of coming up in the actual Certified Fire Inspector I exam.